Bloody ebayers! Can anyone spot basic error in this spec?
Discussion
OK. Am looking for a high power inverter for a boat.
This is the spec of the one I've found.
Electrical Specifications
Max. Continuous Power 3000 watts
Peak Power 6000 watts
AC output voltage 240VAC
AC output frequency 50Hz+5%
AC output waveform Modified Sine Wave
DC input voltage 12V DC
voltage range 10~15VDC
No Land Current Draw <0.8 amps(at 12V input)
LED Indicator Input voltage level, output load level and status
Efficiency (Typ.) >80%
Fuse (12V) 30A *12 (12V)
Bat. Low Alarm 10.5VDC
Bat. Low Shutdown 10.0VDC
Over Load Shut off output voltage, re-power on to recover
Over Voltage 15-16VDC
Cooling Loading controlled cooling fan
Can you see an obvious problem here?
I've had a to-and-fro Q&A session with the seller, will post these up later!
This is the spec of the one I've found.
Electrical Specifications
Max. Continuous Power 3000 watts
Peak Power 6000 watts
AC output voltage 240VAC
AC output frequency 50Hz+5%
AC output waveform Modified Sine Wave
DC input voltage 12V DC
voltage range 10~15VDC
No Land Current Draw <0.8 amps(at 12V input)
LED Indicator Input voltage level, output load level and status
Efficiency (Typ.) >80%
Fuse (12V) 30A *12 (12V)
Bat. Low Alarm 10.5VDC
Bat. Low Shutdown 10.0VDC
Over Load Shut off output voltage, re-power on to recover
Over Voltage 15-16VDC
Cooling Loading controlled cooling fan
Can you see an obvious problem here?
I've had a to-and-fro Q&A session with the seller, will post these up later!
zollburgers said:
30A at 12v is way less than 3kW?
It's not just me then!First question to customer:- If this unit is 3kW why is the input fuse only 30A?
Response :- Pls google 1amp = watts the answer is there
Second question to customer:- That's what I thought. If the fuse is in the 12V circuit (as stated) 30A x 12 V =360W. This does not take into account the efficiency of the unit!
Response :- 30a x 12v = 3600watts. 1amp = 120 watts
I may not be buying this particular unit!

Poledriver said:
zollburgers said:
30A at 12v is way less than 3kW?
It's not just me then!First question to customer:- If this unit is 3kW why is the input fuse only 30A?
Response :- Pls google 1amp = watts the answer is there
Second question to customer:- That's what I thought. If the fuse is in the 12V circuit (as stated) 30A x 12 V =360W. This does not take into account the efficiency of the unit!
Response :- 30a x 12v = 3600watts. 1amp = 120 watts
I may not be buying this particular unit!

i would buy it if it is that efficent!
Fume troll said:
SplatSpeed said:
zollburgers said:
30A at 12v is way less than 3kW?
300 amps ain'tCheers,
FT.
Current drain too high, the weakest fuse blows. The protection of the equipment is now better as it needs lower current to blow the next weakest fuse etc. etc.
I've never seen it done that way before, but it is valid!

I

Poledriver said:
Fume troll said:
SplatSpeed said:
zollburgers said:
30A at 12v is way less than 3kW?
300 amps ain'tCheers,
FT.
Current drain too high, the weakest fuse blows. The protection of the equipment is now better as it needs lower current to blow the next weakest fuse etc. etc.
I've never seen it done that way before, but it is valid!

I

SplatSpeed said:
Poledriver said:
Fume troll said:
SplatSpeed said:
zollburgers said:
30A at 12v is way less than 3kW?
300 amps ain'tCheers,
FT.
Current drain too high, the weakest fuse blows. The protection of the equipment is now better as it needs lower current to blow the next weakest fuse etc. etc.
I've never seen it done that way before, but it is valid!

I

Poledriver said:
SplatSpeed said:
Poledriver said:
Fume troll said:
SplatSpeed said:
zollburgers said:
30A at 12v is way less than 3kW?
300 amps ain'tCheers,
FT.
Current drain too high, the weakest fuse blows. The protection of the equipment is now better as it needs lower current to blow the next weakest fuse etc. etc.
I've never seen it done that way before, but it is valid!

I

SplatSpeed said:
Poledriver said:
SplatSpeed said:
Poledriver said:
Fume troll said:
SplatSpeed said:
zollburgers said:
30A at 12v is way less than 3kW?
300 amps ain'tCheers,
FT.
Current drain too high, the weakest fuse blows. The protection of the equipment is now better as it needs lower current to blow the next weakest fuse etc. etc.
I've never seen it done that way before, but it is valid!

I