Boiler not shutting down properly
Discussion
Hi,
Poterton Performa 18HE
When the stat gets to temp I can hear the 2 pos valve shut off and usually the boiler then runs down for 2 mins then shuts off, sometimes though the boiler switches off instantly, which to my mind is not correct.
Anythings I can have a look out for?
Cheers.
Poterton Performa 18HE
When the stat gets to temp I can hear the 2 pos valve shut off and usually the boiler then runs down for 2 mins then shuts off, sometimes though the boiler switches off instantly, which to my mind is not correct.
Anythings I can have a look out for?
Cheers.
When the valve shuts the burner should stop instantly. What you hear then is the pump overrun circuit running the pump to disperse the heat. I would have thought it would be on a timer in the PCB. It MAY have a thermostat though. Either way, heat soak is the enemy of the low water content boiler.