indicators blowing fuses
Discussion
So here it is,
The fuse for the indicators is blowing. Cant be one of the lamps itself as the hazzards work fine. Its a wierd one. I change the fuse, start the car and everything is fine. I can drive for an hour no probs with anything but if I stop, switch off, go away for 10 mins then come back and start up, the fuse blows. It is as if there is a short occuring when either switching the ignition on or off. Anyone experienced this or have any ideas or even have an electrical diagram of the indicator wiring.
I know im probably peeing in the wind here and going to have to trace it out to find the short
The fuse for the indicators is blowing. Cant be one of the lamps itself as the hazzards work fine. Its a wierd one. I change the fuse, start the car and everything is fine. I can drive for an hour no probs with anything but if I stop, switch off, go away for 10 mins then come back and start up, the fuse blows. It is as if there is a short occuring when either switching the ignition on or off. Anyone experienced this or have any ideas or even have an electrical diagram of the indicator wiring.
I know im probably peeing in the wind here and going to have to trace it out to find the short
Put a bigger fuse in.....
Sorry, standard electrician reply.
Do check though that the fuse is the correct rating at 15A.
It wont be an easy fault to find if its a wiring fault, you will have to bite the bullet and visually check all connections and voltages/resistances in the circuit....but check the relay and flasher box in case of water ingress/moisture/general brokeness.
Wiring diagrams are here:
http://www.thetvrsite.com/cerbera/wiring-diagrams
Sorry, standard electrician reply.
Do check though that the fuse is the correct rating at 15A.
It wont be an easy fault to find if its a wiring fault, you will have to bite the bullet and visually check all connections and voltages/resistances in the circuit....but check the relay and flasher box in case of water ingress/moisture/general brokeness.
Wiring diagrams are here:
http://www.thetvrsite.com/cerbera/wiring-diagrams
well a bit of investigation has brung some new developments. The fuse for the indicators is blowing when I select reverse gear. I can only think that the reverse switch and circuit is off the same circuit as the indicators. I checked the reverse lamp and its fine. Got the meter on the fuse terminal and there is a direct short to earth when reverse is selected. Wierd one. Going to get the gaitor off tomorrow and check the switch.
does anyone have a wiring diagram
does anyone have a wiring diagram