Fans not working, and other issues!
Fans not working, and other issues!
Author
Discussion

cjs

Original Poster:

11,653 posts

280 months

Monday 11th April 2011
quotequote all
Was out in my Pre-Cat Griff on Sunday, noticed the engine temperature creeping up, the fans were not kicking in, so it could be just a fuse, if so does any one know which one it may be? 40A?

However....

Recently I have noticed an intermittent buzzing sound coming from what I suspect is a relay in the passenger foot-well. I noticed this more when accelerating in a higher gear, as I pulled away the relay would buzz.

Do the fans use a relay? Maybe this has gone? If so does anyone know which one?

Where is the temperature sensor for the fans? Is this the one at the bottom of the swirl pot? I may need to bypass this to test the system.

There were other issues whilst I was out, could be related? Whilst driving, the engine revs would not drop below 1800-2k, not until I slowed to a stop when they went back to usual tick over, around 900. I was also getting a misfire when accelerating, especially if I was labouring the engine slightly in a higher gear.


So any suggestions ideas?


Edited by cjs on Monday 11th April 18:10


Edited by cjs on Monday 11th April 18:11

Colin RedGriff

2,541 posts

286 months

Monday 11th April 2011
quotequote all
Yes the fans are operated by a relay, or possibly two, depending how many they could find in the factory on that day!rolleyes

Colin RedGriff

2,541 posts

286 months

Monday 11th April 2011
quotequote all
Yes the fans are operated by a relay, or possibly two, depending how many they could find in the factory on that day!rolleyes

cjs

Original Poster:

11,653 posts

280 months

Monday 11th April 2011
quotequote all
spend said:
It's a precat! only 1 relay............
Any idea which one? Will it be on the fuse box or in the 'spaghetti' in the foot-well box?

cjs

Original Poster:

11,653 posts

280 months

Thursday 21st April 2011
quotequote all
Ok, managed to find out why the fans are not working, one of them has seized up! This was blowing the 25A fuse, I have now disconnected the dodgy fan and all is ok with one fan running.

I reckon the dead fan is an original, I replaced one of them around 5 years ago, now need to source a replacement fan.

Interesting a 25A fuse and a 30A relay are running the twin fans, these are rated at 25A each, although I have never had a fuse blow on me until now.

jimed

1,508 posts

235 months

Friday 22nd April 2011
quotequote all
Maybe you can lubricate the sticky fan and free it off - worth a try as I've heard of that being done before.
Jim

cjs

Original Poster:

11,653 posts

280 months

Friday 22nd April 2011
quotequote all
jimed said:
Maybe you can lubricate the sticky fan and free it off - worth a try as I've heard of that being done before.
Jim
I'll take a look however there was a electrical burning smell when the problems with the fan arose, the fan was also a bit noisy before it died, I reckon the motor has burnt out.

cjs

Original Poster:

11,653 posts

280 months

Friday 22nd April 2011
quotequote all
The Fan I need is a Spal VA10-AP9/C-25A. Anyone know a good , cheap, source? Spal UK are quoting £140!! I'm sure I paid around £40 for the last one, that was 5 years ago though, just need to find the paperwork.

Also, silly me, the 25A is a bit of the part number, not the amperage, they are actually 7A each, so only 14A on my 25A fuse, so well within limits.

jimed

1,508 posts

235 months

Saturday 23rd April 2011
quotequote all
You could try one of the TVR breakers (Douglas Valley and Bellhill Garage) and see if they have one - could be worth trying for a new price as well as some of the breakers want silly money.
Jim