Trying to sort out the aesthetics of the wood burner install in our new place. We'd like the flue to emerge from the top of the stove (Firebelly FB1) run up to the ground floor ceiling, then emerge directly above and run the rest of the way to the ceiling at the top of the atrium (double height space) naturally it'll need to be twin wall through the floor. But can it become single skin again on the way up to the roof?

Alternatively is it possible to connect in a twin wall that looks neat and clean on the stove top? its a 125mm connector. Ideally we'll have the same diameter flue below and above the floor to give a consistent look and line through the building,

anonymous-user

55 months

Thursday 26th January 2017
quotequote all
Twin wall throughout, why not contact a solid fuel association engineer?

Tom_C76

1,923 posts

189 months

Thursday 26th January 2017
quotequote all
If there's a floor in the way will you ever see both sections of flue at the same time?

Lesgrandepotato

Original Poster:

372 posts

100 months

Thursday 26th January 2017
quotequote all
Tom_C76 said:
If there's a floor in the way will you ever see both sections of flue at the same time?
The flue just nicks part of a landing floor - so yes you'll see it top to bottom - hence trying to get the aesthetic right

Tom_C76

1,923 posts

189 months

Thursday 26th January 2017
quotequote all
The collars at floor penetration in twinwall are big and not pretty. I'd look to reengineer the floor to give clearance for single wall stovepipe assuming you can get a safe clearance around it.

V8RX7

26,961 posts

264 months

Thursday 26th January 2017
quotequote all
After much messing about with Flue suppliers the answer is yes, you can connect twinwall directly to the stove using a starter piece.

You may have to pack / cut down your stove's outlet.

However my research was with 6" internal - I presume 5" is the same.




bobtail4x4

3,730 posts

110 months

Thursday 26th January 2017
quotequote all
most stoves need a 6 inch flue.

roofer

5,136 posts

212 months

Thursday 26th January 2017
quotequote all
And no, you can't change back to single skin.