Hi i have a new Central Heating timer that i need a little help with on how to wire it up,
This is what it says on how to wire it

N L 1 2 3 4

Mains Fused HW OFF CH OFF HW ON CH ON

Any ideas?
Thanks

Ricky_M

6,618 posts

220 months

Tuesday 20th October 2009
quotequote all
N and L are your 230v live and neutral supply to power the clock.

CH off you won't need.

HW off you may need if you have a 3 port valve instead off 2x 2 port valves. If you do have a 3 port valve, it should be wired up to the grey wire on your 3 port valve. Don't quote me as some valves use different coloured wires.

HW on should be wired to the common on your cylinder stat

CH on should be wired to the common on your room stat

chriz1

Original Poster:

669 posts

216 months

Tuesday 20th October 2009
quotequote all
im not sure what valves i got or how many all i know is this system is about 40 years old

Ricky_M

6,618 posts

220 months

Tuesday 20th October 2009
quotequote all
Chances are you'll have gravity hot water and pumped heating.

Try the honeywell website, they usually have step by step guides for wiring of new programmers, doesn't matter if the new one you have isn't honeywell as most new programmers use the same format.

chriz1

Original Poster:

669 posts

216 months

Tuesday 20th October 2009
quotequote all
thanks will try it now