Wedge AFM issues
Discussion
Learning fast about wedges with all the info out there but one problem ive not come across on any forum. 350i 4CU air flow meter, the voltage measured across terminals 6 and 7 of the ECU actually increases as the flapper is opened from 0.5 to 2.7, Understand it should decrease from 3.7 down to 1.6. Inside the case all looks as new and all other tests as they should be except fuel pump runs continuous with ignition on but switches off when the flapper is opened. Any ideas?