Duratec over cooling

Duratec over cooling

Author
Discussion

Mr MXT

Original Poster:

7,692 posts

284 months

Thursday 8th June 2017
quotequote all
Thought this would be the best section, having trouble with my Duratec in a Westfield plumbed thus



previously, engine ran at 85-90 degrees with no issues, a holed rad meant I rplaced the standard old rad with a 55mm coolex.

Since then, when the engine gets up to temperature, if I hold it at WOT, the water temperature drops right down, can get as low as 40 if the road is straight enough....

I've changed the stat with no avail.

On the advice ofsome zetec owners I've drilled a small hole in the thermostat to get the flow going. This didn't help, the car ran at 100 degrees and warmed up worryingly fast..

I'veput an undrilled stat back in.

Any ideas ?

Mr MXT

Original Poster:

7,692 posts

284 months

Friday 9th June 2017
quotequote all
andyf1140 said:
Have you tried the turbosport forum? They have a lot of experience of Duratec installations...
No, but I will. Good shout, thanks.


Frankthered said:
Is the water temperature sensor on the radiator, or in that part of the circuit?

If so, do you have a separate sensor on the engine?

If the water coming back from the rad is that cool, the stat should reduce the flow to the rad to keep the engine at its optimum temperature. To be honest, it sounds like your new rad has some additional cooling capacity that you didn't really need, but your stat should keep the engine happy.
Temp sensor is where the coolant exits the head. I only "upgraded" as I had a hole in the previous rad, I wasn't suffering any overheating issues even when on track for 40 mins at a time.

You can see in the diagram, there is a bypass that circulates the coolant back to the head when cold, to speed warm up, then the stat isn't open / close, it bypasses the bypass, so the coolant flows round the rad once warm.

Its as if the stat doesn't close quick enough, so the engine gets a massive glug of cool coolant that has been sat in the rad....