Replacing counterbattens on old roof frame: Bad idea?

Replacing counterbattens on old roof frame: Bad idea?

Author
Discussion

WeezeeDriver

Original Poster:

44 posts

72 months

Wednesday 16th April
quotequote all
I live in one-half of an old chapel that was converted in 2000. The roof has become a bit wrecked by solar panels, birds, etc. so I planned to replace the felt and pantiles. The roofer discovers it has counterbattens and the building control plans seem to confirm this. The trusses are pretty old - has anybody got experience of replacing felt on a converted building like this? I'm kind of worried about the damage that may be inflicted on the trusses when the counterbattens are removed.

hidetheelephants

30,351 posts

208 months

Wednesday 16th April
quotequote all
Are the counterbattens causing a problem to necessitate removal? It looks like they're there to allow the tyvek to do its job.

WeezeeDriver

Original Poster:

44 posts

72 months

Wednesday 16th April
quotequote all
hidetheelephants said:
Are the counterbattens causing a problem to necessitate removal? It looks like they're there to allow the tyvek to do its job.
The counterbattens aren't causing any problems it is the tyvek that needs replacing in places, and to do that you have to take the counterbattens off - the roofer suggested leaving the counterbattens and the tyvek where they are and placing another layer of tyvek on top - this is not ideal but the trusses are very old.

Cow Corner

556 posts

45 months

Wednesday 16th April
quotequote all
I can’t read the drawing you’ve snipped, but if you’re going to the trouble and expense of replacing the roof then I would strip the counter battens and replace the breather membrane at the same time. Leaving the original behind and doubling them up is a bodge and is unlikely to comply with the manufacturers details.

If you are replacing the whole roof then you will need to submit an application to building control anyway, so they’ll need to be satisfied.

If the condition of the roof structure is such that you are concerned by the damage caused by removing and refixing the counter battens, then you may have a bigger problem.

Is the building listed or in a conservation area?

WeezeeDriver

Original Poster:

44 posts

72 months

Wednesday 16th April
quotequote all
Cow Corner said:
I can’t read the drawing you’ve snipped, but if you’re going to the trouble and expense of replacing the roof then I would strip the counter battens and replace the breather membrane at the same time. Leaving the original behind and doubling them up is a bodge and is unlikely to comply with the manufacturers details.

If you are replacing the whole roof then you will need to submit an application to building control anyway, so they’ll need to be satisfied.

If the condition of the roof structure is such that you are concerned by the damage caused by removing and refixing the counter battens, then you may have a bigger problem.

Is the building listed or in a conservation area?
Sorry about the text in the pic.

The building isn't listed or in a conservation area - but it is divided into two halves so I am replacing all the old pantiles because they are in very poor condition with newer reclaimed pantiles. Do you need to contact building control for replacing the felt and tiles? I wasn't thinking of doing anything with the original structure of the roof.

Cow Corner

556 posts

45 months

Wednesday 16th April
quotequote all
If you are replacing more than 50% of the roof then you will need to submit a building control application.

It’s a pretty straightforward process, the only potential issue may be that they will want you to upgrade the thermal insulation as part of the work, but given it’s a historic building and was only converted in 2000, this may require a commmon sense discussion with Building Control - others might be better placed to advise on that.

WeezeeDriver

Original Poster:

44 posts

72 months

Wednesday 16th April
quotequote all
Cow Corner said:
If you are replacing more than 50% of the roof then you will need to submit a building control application.

It’s a pretty straightforward process, the only potential issue may be that they will want you to upgrade the thermal insulation as part of the work, but given it’s a historic building and was only converted in 2000, this may require a commmon sense discussion with Building Control - others might be better placed to advise on that.
Thanks for that advice, the thermal insulation was updated around about 2022, when I had some solar panels installed - so that probably would not be an issue.

Aluminati

2,912 posts

73 months

Wednesday 16th April
quotequote all
Your roofer is going for the dodge.

There will be minimal, if any damage by removing battens.

WeezeeDriver

Original Poster:

44 posts

72 months

Wednesday 16th April
quotequote all
Aluminati said:
Your roofer is going for the dodge.

There will be minimal, if any damage by removing battens.
Yeh, it sounds a lot easier to just layer on top smile We could do the rear first and see how it goes - that includes all the flues, etc.